Basements

Basement damp and seepage, treated from inside

You cannot dig out a finished basement. Foam closes the cold joint, the tie holes and the crack — from the dry side.

  • Application
  • Component A
  • Full method below

What goes wrong on site

Three failures, in the order they appear

  • 01

    Seepage on the negative side, where no membrane can be applied.

  • 02

    Damp that becomes mould behind the lining, out of sight.

  • 03

    No excavation possible: the building is finished and occupied.

Why one-component foam, and not something else

Three properties, no chemistry

  • Mobility: a can and a gun reach a joint that a panel, a board or a truck cannot.
  • Irregular geometry: it expands to the shape of the void, including penetrations.
  • Closed cell: air barrier and moisture barrier in one pass, without a second trade.

How it is done, and what to hold

The four numbers this job lives on

StepWhat to hold
SurfaceJoint and cracks opened and cleaned, loose render removed, active running water stopped first.
Fill volumeOne third of the joint depth. The foam expands to fill; filling it to the top bends frames and wastes material.
PassesTwo passes of 30 mm at most. A single thick pass traps heat and collapses in the core.
TrimCut after the window on the parameter card. Never pull or press uncured foam.
CoverPU is not UV-stable. Any exposed face gets sealant, render or a trim within 48 hours.

Typical guidance. The parameter card for your grade carries the tolerances your operators work to.

Common failures

Three ways this job goes wrong

  1. Foaming over a wet wall: the foam skins, the water stays behind it.
  2. Treating foam as a waterproofing membrane. It is not one.
  3. Sealing the crack without relieving the pressure — it finds another line.
→

Component A

Component A behind a drained cavity, with a cementitious waterproof coat on the face. Foam is the second line, not the first.

See specification

What to tell your customer

Three sentences you can copy into a quotation, a WhatsApp message or a site meeting. Your competitors' websites talk about themselves; this block is for you to talk about the job.

„We stop the water first, then foam. Foam behind a wet wall does nothing.“

„The cold joint and the tie holes are the two places water always enters.“

„This is a drained-cavity detail, not a paint-on coating.“

Send the drawing or the photo — we will reply with the parameters.

Talk to an engineer

Technology brand

Tell us the joint, the substrate and the season