Parameter cards
The numbers your operators actually touch
A parameter card is not a datasheet. The datasheet describes what we ship; the card describes what your shift does with it. Six numbers, one page, laminated.
The card
Six lines, and no seventh
| Parameter | Set point | Tolerance | Measured at |
|---|---|---|---|
| Drum temperature at feed | 18–25 °C | ±3 °C | Probe in the drum, not the room |
| Ambient temperature | 15–30 °C | ±5 °C | At the filling head |
| Relative humidity | < 75% | — | At the filling head |
| Fill weight | Per the card | ±2 g | 5 cans per hour, calibrated scale |
| Propellant pressure | Per the card | ±0.2 bar | At the gas head, every hour |
| Cutting window | 35–50 min | ±5 min | First can of each shift |
What this card deliberately does not contain: formulation ratios. Those stay with us and with your mixing instructions — they are not something to print on a wall.
Ask for the card set for your can size.
Technology brand
Request the technology package index
- 1 tonne minimum, five 200 L drums
- SDS, COA and Form E with every shipment
- We reply within 24 hours, Monday to Saturday.